Products Description
Key Functions and Technical Features
OCV and IR Testing
Accurate electrical testing is the foundation of reliable battery cell classification.
The system performs barcode identification and electrical testing to evaluate individual pouch cells according to defined production criteria.
| Testing Function | Description |
|---|---|
| OCV Measurement | Open Circuit Voltage measurement |
| IR Measurement | Internal Resistance measurement |
| K-Value Testing | K-value testing according to the specified project process |
| Grading Comparison | Comparison against predefined cell specifications |
| NG Identification | Automatic identification of nonconforming cells |
| Data Binding | Barcode-to-test-data binding |
| Data Storage | Local storage of testing data |
| Testing Design | Technical Description |
|---|---|
| Probe Contact Design | Addresses surface oxidation on cell terminals to help reduce measurement errors and false grading |
| Testing Standards | Stores testing standards for multiple cell models |
| Standard Selection | Selects corresponding criteria according to production information or manual changeover |
Automatic Cell Sorting
After testing, the transfer mechanism moves cells to their corresponding sorting positions according to the measurement results.
| Sorting Function | Description |
|---|---|
| Automatic Classification | Cell classification based on OCV/IR results |
| Automatic Transfer | Transfer to designated sorting positions |
| NG Separation | Separation of voltage NG, IR NG and barcode NG cells |
| NG Buffering | Dedicated NG buffering |
| Qualified Cell Transfer | Automatic transfer of qualified cells to downstream grouping processes |
This arrangement helps prevent nonconforming cells from entering subsequent module assembly operations.
Multi-Channel Sorting and Buffering
The multi-channel sorting system is designed to organize cell flow between electrical testing and downstream grouping.
| Parameter | Reference Project Specification |
|---|---|
| Sorting Channels | 10 channels |
| Maximum Buffer Capacity | 8 cells per channel |
| Buffer Conveyor | Two-level arrangement |
| Cell Width Reference | 200 mm |
A two-level buffer conveyor arrangement is adopted to optimize equipment space and support organized material flow.
Barcode Identification and Data Traceability
Barcode identification connects individual cell information with the corresponding electrical testing results.
| Data Management Function | Description |
|---|---|
| Barcode Scanning | Automatic barcode scanning |
| Cell Identification | Cell identification and test-data binding |
| Test Data Recording | OCV/IR result recording |
| Cell Classification | Automatic cell grading |
| Data Storage | Local storage of testing data |
| NG Identification | Identification of barcode-related NG conditions |
External data communication and MES integration requirements should be confirmed according to the customer's production system and project interface specifications.
Customized Integration with Battery Module and PACK Lines
The pouch cell sorting system can be integrated with upstream cell feeding and downstream module grouping processes.
Depending on the approved product specifications, the complete production system can coordinate the following processes:
| Production Section | Process Sequence |
|---|---|
| Cell Processing and Sorting | Cell Loading → Barcode Scanning → OCV/IR Testing → Cell Classification → Automatic Sorting → NG Separation → Cell Grouping → Module Assembly |
The equipment configuration is customized according to the customer's cell dimensions, terminal structure, testing requirements, target production capacity and factory layout.
Key Technical Specifications
| Parameter | Reference Project Specification |
|---|---|
| Equipment Type | Automatic Pouch Cell Testing and Sorting System |
| Battery Cell Type | Pouch Lithium Battery Cells |
| Testing Items | OCV, IR, K-value and grading comparison |
| OCV Tester | Hioki BT3561A |
| Voltage Accuracy | ±0.01% rdg ±5 dgt |
| Internal Resistance Accuracy | ±0.5% rdg ±5 dgt |
| Barcode Scanner | Keyence SR-1000W |
| Barcode Data Binding | Supported |
| Testing Data Storage | Local storage |
| Sorting Channels | 10 channels |
| Maximum Buffer Capacity | 8 cells per channel |
| Buffer Conveyor | Two-level arrangement |
| NG Classification | Voltage NG, IR NG and Barcode NG |
| NG Buffer Capacity | 1–8 cells per buffer position, based on 200 mm cell width |
| Cell Transfer | Automatic transfer to designated sorting positions |
Reference Cell Compatibility
The following dimensional ranges are specified for the associated customized pouch cell production line.
Final sorting-machine compatibility must be confirmed against approved cell samples, terminal configurations and tooling requirements.